Description
- DATA SERVER The file name set to DNC operation at the time of the Storage mode of DATA SERVER function is taken out with a full path.
- DATA SERVER Host The file name set to DNC operation at the time of the FTP mode or buffer mode of DATA SERVER function is taken out with a full path.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
#include "fwlib32.h" or "fwlib64.h"FWLIBAPI short WINAPI cnc_rddsdncfile(unsigned short FlibHndl, char *dev_name, short *host, char *dncfile);
Arguments
Specify the library handle. See "Library handle" for details.
Specify the device name is as follows:
-
DATA SERVER : "DATA_SV" DATA SERVER Host : "DTSVR_HOST"
The pointer to the variable area which stores the connection host number is specfied.
The numerical value of 1 to 3 returns.
However, when the file for DNC operation is not set up, 0 returns.
The current file name to receive 256 bytes or less of ASCII characters string including NULL.
When the file for DNC operation is not set up, only NULL may return.
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
(6) |
In order to get more information for this err_no return value, execute cnc_getdtailerr() function. The following details status will be set onto the member, err_no of ODBERR structure.
|
|||||||||
(5) |
The Specification of dev_name is wrong. |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
For HSSB connection,
The DATA SERVER function and the extended driver/library function are necessary.
CNC parameter
This function is not related to CNC parameter.
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | X |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.
See Also