Description
Changes FOCAS2 library's optional specifications dynamically.
The changeable options are as follows.
Value(optname) | Type | Default | Meaning |
LIB_MODE(0) | long | 0 | Changes the advanced mode(0) or the traditional mode(1). |
MOVE_RDPRGPTR(1) | long | 1 | Changes if the execution pointer would be moved(1) or not moved(0) after invoking cnc_rdpdf_line function. |
(As for the advanced/traditional mode, see "FS16i compatible mode")
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments
Specify the library handle. See "Library handle" for details.
Specify the kind of the option to be set.
Specify the pointer to data to be set.
Specify the bytes size of the data(*optval) to be set.
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling |
---|---|
(2) |
Size(optlen) is wrong. |
(4) |
Kind of the option(optname) is wrong. |
(5) |
Data of the option(*optval) is out of range. |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
For HSSB connection,
For Ethernet connection,
The Ethernet function and the extended driver/library function are necessary. However, in case of Series 0i-F, 30i and PMi-A, the required CNC option is as follows. When Embedded Ethernet is used,above two optional functions are not required.
When Ethernet board is used,
- only Ethernet function is required.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | H |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.
See Also