Description
Reads the alarm history data. The unit of one alarm history data is called a record.
The operation history data and the alarm history data are automatically recorded on the CNC. When these data are accessed, it is necessary to temporarily stop sampling on the CNC. Therefore, it is necessary to execute "Stop logging operation history data"(cnc_stopophis) before this function is used.
And it is necessary to execute "Restart logging operation history data" (cnc_startophis) after reading to make the sampling stop time of the history data as short as possible.
The start/end record number means the relative number uesd at reading the alarm history data. These record numbers are valid only at the period from the execution of "Stop logging operation history data" until the execution of "Restart logging operation history data".
The alarm history data is acquired in old order.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments : HSSB
Specify the library handle. See "Library handle" for details.
Specify the start record number. (specify 1 or more.)
Specify the end record number. (specify 1 or more.)
Specify the data block length. (size of ODBAHIS3 structure)
Pointer to the ODBAHIS3 structure in which the alarm history data is stored. The ODBAHIS3 structure is as follows.
typedef struct odbahis3 {
unsigned short s_no; /* Start record number */
short type; /* Not used */
unsigned short e_no; /* Most recently entered */
/* record number */
struct {
short dummy; /* Not used */
short alm_grp; /* Alarm type */
short alm_no; /* Alarm number */
char axis_no; /* Axis number */
char year; /* Year */
char month; /* Month */
char day; /* Day */
char hour; /* Hour */
char minute; /* Minute */
char second; /* Second */
char dummy2; /* Not used */
short len_msg; /* Length of alarm */
/* messafe */
char alm_msg[36]; /* Alarm message */
} alm_his[N]; /* N : Number of record */
} ODBAHIS3 ;
- alm_grp
- unused
- alm_no
- Alarm number
- axis_no
- Axis number (1 - maximum axis control number) It is unused for an unrelated alarm to the axis.
- year
- Year (0,..,99)
- month
- Month (1,..,12)
- day
- Day (1,..,31)
- hour
- Hour (0,..,23)
- minute
- Minite (0,..,59)
- second
- Second (0,..,59)
- len_msg
- Number of characters of alarm message (0 - 33)
- alm_msg
- Message string
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling |
---|---|
(1) |
cnc_stopophis function has not been executed. |
(2) |
Size of ODBAHIS3 structure(length) is wrong. (e_no-s_no+1) * sizeof(data[0]) + 6 > length |
(3) |
The specification of the record number (s_no, e_no) is wrong. |
(6) |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
For HSSB connection,
CNC parameter
This function is not related to CNC parameter.
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.