Description
Reads the management time data.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments
Specify the library handle. See "Library handle" for details.
Specify the reading start number of management time data. (0,1,2,...)
Specify the pointer to the variable where the number of management time which wants to be acquired was setted.
This function returns the number of data which was read actually.
Specify the pointer to the array of IODBMNGTIME structure to store the management time data. The number of array must be equal to "number".
The IODBMNGTIME structure is as follows.
typedef struct iodbmngtime {
unsigned long life; /* Setted life(setting time) */
unsigned long total; /* Total management time(managemant time) */
} IODBMNGTIME;
- life
- Setted life(setting time) (0~99999999)
- total
- Total management time(managemant time) (0~99999999)
- setting unit 1 = 0.1 hour
- * When the setted life is "0", the management time is not counted.
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling |
---|---|
(1) |
This function cannot be used except 16i/18i-L, 30i/31i-LB. |
(3) |
Start number(s_no) is wrong. |
(2) |
Number of data(number) is wrong. |
(6) |
The extended driver/library function are necessary. |
(9) |
Mistake of laser oscillator (parameter No.15030) |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
For HSSB connection,
For Ethernet connection,
The Ethernet function and the extended driver/library function are necessary. When Embedded Ethernet is used,above two optional functions are not required.
When Ethernet board is used,
- only Ethernet function is required.
CNC parameter
This function is related to the following CNC parameter.
See the manual of CNC parameter for details.
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | - |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.