Description
CNC is reset.
When this function is executed, reset is executed to all paths or the path selected bt CNC according to set value of parameter No.8100#0(RST) of 1st path.
Note) | : | In case of M system, if this function is executed during the background drawing when the set value of parameter No.8100#0(RST) is 1, the background drawing is not reset but the processing side is reset. When the set value of parameter No.8100#0(RST) is 0, both of the background drawing and the processing side are reset. |
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments
Specify the library handle. See "Library handle" for details.
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling |
---|---|
(1) |
This function is not supported by CNC. |
(6) |
The extended driver/library function is necessary. |
(13) |
Path selected by path select signal is emergency stop or reset status.(30i/31i/32i, 0i-D/F only) |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
For HSSB connection,
CNC parameter
This function is related to the following CNC parameter.
See the manual of CNC parameter for details.
No.8100#0(RST) influenced by setting
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | H |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.