Description
Writes the output signal of software operator's panel.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments
Specify the library handle. See "Library handle" for details.
Pointer to the IODBSGNL structure to set the output signal of software operator's panel.
The IODBSGNL structure is as follows.
Series 15/15i
typedef struct iodbsgnl {
short datano; /* (Not used) */
short type; /* Data select flag */
short mode; /* Mode signal */
short hndl_ax; /* Manual handle feed axis selection signal */
short hndl_mv; /* Manual handle feed travel distance selection signal */
short rpd_ovrd; /* Rapid traverse override signal */
short jog_ovrd; /* Manual feedrate override signal*/
short feed_ovrd; /* Feedrate override signal */
short spdl_ovrd; /* Spindle override signal (only Series 15i) */
short blck_del; /* Optional block skip signal(0/1)*/
short sngl_blck; /* Single block signal(0/1) */
short machn_lock; /* Machine lock signal(0/1) */
short dry_run; /* Dry run signal(0/1) */
short mem_prtct; /* Memory protection signal(0/1) */
short feed_hold; /* Automatic operation halt signal(0/1) */
short manual_rpd; /* (Not used) */
short dummy[2]; /* (Not used) */
} IODBSGNL ;
Series 16/18/21, 16i/18i/21i, 0i, 30i, Power Mate i, PMi-A
typedef struct iodbsgnl {
short datano; /* (Not used) */
short type; /* Data select flag */
short mode; /* Mode signal */
short hndl_ax; /* Manual handle feed axis selection signal */
short hndl_mv; /* Manual handle feed travel distance selection signal */
short rpd_ovrd; /* Rapid traverse override signal */
short jog_ovrd; /* Manual feedrate override signal*/
short feed_ovrd; /* Feedrate override signal */
short spdl_ovrd; /* (Not used) */
short blck_del; /* Optional block skip signal(0/1)*/
short sngl_blck; /* Single block signal(0/1) */
short machn_lock; /* Machine lock signal(0/1) */
short dry_run; /* Dry run signal(0/1) */
short mem_prtct; /* Memory protection signal(0/1) */
short feed_hold; /* Automatic operation halt signal(0/1) */
} IODBSGNL ;
- datano
- Not used
- type
- Specify the data selection flag.
bit 0 : Mode signal bit 1 : Manual handle feed axis selection signal bit 2 : Manual handle feed travel distance selection signal bit 3 : Rapid traverse override signal bit 4 : Manual feedrate override signal bit 5 : Feedrate override signal bit 6 : Spindle override signal (only Series 15i) bit 6 : (Not used) bit 7 : Optional block skip signal bit 8 : Single block signal bit 9 : Machine lock signal bit 10 : Dry run signal bit 11 : Memory protection signal bit 12 : Automatic operation halt signal bit 13 : (Not used) bit 14 : (Not used) bit 15 : (Not used) * When the bit corresponding to the signal is set to 0, that signal is not written. To write the signal, set the corresponding bit to 1.
- mode
- Specify the mode signal.
- Series 15/15i
0 : MDI 1 : MEM 2 : EDIT 3 : HND 4 : JOG 5 : REF 6 : DNC 7 : INC - Series 16/18/21, 16i/18i/21i, 0i, 30i, Power Mate i, PMi-A
0 : MDI 1 : MEM 2 : EDIT 3 : HNDL or INC 4 : JOG 5 : REF - hndl_ax
- Specify the manual handle feed axis selection signal.
0 : HX 1 : HY 2 : HZ 3 : H4 - hndl_mv
- Specify the manual handle feed travel distance selection signal.
0 : ×1 1 : ×10 2 : ×100 - rpd_ovrd
- Specify the rapid traverse override signal.
0 : 100% 1 : 50% 2 : 25% 3 : F0 - jog_ovrd
- Specify the manual feedrate override signal.
0 : 0% 10 : 2.0% 20 : 52.0% 1 : 0.1% 11 : 2.7% 21 : 72.0% 2 : 0.14% 12 : 3.7% 22 : 100% 3 : 0.2% 13 : 5.2% 23 : 140% 4 : 0.27% 14 : 7.2% 24 : 200% 5 : 0.37% 15 : 10.0% 6 : 0.52% 16 : 14.0% 7 : 0.72% 17 : 20.0% 8 : 1.0% 18 : 27.0% 9 : 1.4% 19 : 37.0% - feed_ovrd
- Specify the feedrate override signal.
0 : 0% 10 : 100% 20 : 200% 1 : 10% 11 : 110% 2 : 20% 12 : 120% 3 : 30% 13 : 130% 4 : 40% 14 : 140% 5 : 50% 15 : 150% 6 : 60% 16 : 160% 7 : 70% 17 : 170% 8 : 80% 18 : 180% 9 : 90% 19 : 190% - spdl_ovrd
- Specify the spindle override signal. (only Series 15i)
0 : 0% 10 : 100% 20 : 200% 1 : 10% 11 : 110% 2 : 20% 12 : 120% 3 : 30% 13 : 130% 4 : 40% 14 : 140% 5 : 50% 15 : 150% 6 : 60% 16 : 160% 7 : 70% 17 : 170% 8 : 80% 18 : 180% 9 : 90% 19 : 190% - Not used
- blck_del
- Specify the optional block skip signal (0/1).
- sngl_blck
- Specify the single block signal (0/1).
- machn_lock
- Specify the machine lock signal (0/1).
- dry_run
- Specify the dry run signal (0/1).
- mem_prtct
- Specify the memory protection signal (0/1).
- feed_hold
- Specify the automatic operation halt signal (0/1).
- manual_rpd
- Not used.
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling |
---|---|
(5) |
In order to get more information for this err_no return value, execute cnc_getdtailerr function. The item including incorrect data (the bit position in the data selection flag (type)) will be set onto the member, err_dtno of ODBERR. |
(6) |
The software operator's panel function and the extended driver/library function are necessary. |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
This function need the following CNC option.
For HSSB connection,
For Ethernet connection,
The Ethernet function and the extended driver/library function are necessary. However, in case of Series 16i/18i/21i-B, 0i-B/C/D/F, Series 30i and PMi-A, the required CNC option is as follows. When Embedded Ethernet is used,above two optional functions are not required.
When Ethernet board is used,
- only Ethernet function is required.
CNC parameter
This function is not related to CNC parameter.
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | O |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.
See Also