Description
Reads the available number of interference check data.
It is stored in (*intinf) with binary format.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments
Specify the library handle. See "Library handle" for details.
Pointer to the available number of interference check data.
The available number is as follows.
- Series 15
- Series 16/18, 16i/18i, 0i-F, 30i
T series | 16/32/80 sets(each path) |
M series | 1 set(each path) |
T series | 16/32/64 sets(each path) |
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling |
---|---|
(1) |
This function cannot be used without 2 path control function. |
(6) |
The tool post interference check option (T series) or the multi-path interference check option (M series), and the extended driver/library function are necessary. |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
This function need the following CNC option.
This function also needs the tool post interference check option (T series) or the multi-path interference check option (M series).
And this function is related to the following CNC option.
- Series 15 T series Tool offset extension (16)/32/80 sets(each path)
- Series 16/18, 16i/18i, 0i-F, 30i T series Tool offset extension (16)/32/64 sets(each path)
* () : Basic
For HSSB connection,
For Ethernet connection,
The Ethernet function and the extended driver/library function are necessary. However, in case of Series 16i/18i-B, 0i-F and 30i, the required CNC option is as follows. When Embedded Ethernet is used,above two optional functions are not required.
When Ethernet board is used,
- only Ethernet function is required.
CNC parameter
This function is not related to CNC parameter.
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | X |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.
See Also