Description
To downloading of PMC parameter, this function, pmc_wrpmcparam and pmc_wrprmend is used.
The procedure of downloading the PMC parameter is shown as follows.
* | Repeatedly download the PMC parameter until the return value of pmc_wrpmcparam becomes excepting EW_OK or writing data is lost. |
* | Judge final result of the downloading of PMC parameter from the return value of pmc_wrprmend. |
* | In case of 0i-F, 30i/31i/32i, please beforehand select the PMC unit type which becomes the object by pmc_select_pmc_unit. |
When you execute this function, set '1' for PWE of the CNC parameter and make the state of CNC an emergency stop.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments : HSSB
Specify the library handle.
See "Library handle" for details.
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling |
---|---|
(-1) |
pmc_rdprmstart or pmc_wrprmstart function has been already executed. |
(6) |
|
(9) |
CNC parameter(PWE) is '0'. |
(13) |
CNC is not in "Emergency" state. |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
For HSSB connection,
CNC parameter
This function is related to the following CNC parameter.
See the manual of CNC parameter for details.
No.8900#0(PWE) (must be set)
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | X |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.
See Also
pmc_rdprmstart pmc_rdpmcparam pmc_rdprmend pmc_wrpmcparam pmc_wrprmend