Description
Reads the parameter of the PROFIBUS slave function.
The status data is added to pbs_rd_param
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments
Specify the library handle. See "Library handle" for details.
Specifies the pointer to the OUT_PBSPRM2 structure to store the the acquired parameter.
The OUT_PBSPRM2 structure is as follows.
typedef struct _OUT_PBSPRM2{
unsigned char slave_no;
unsigned char pad;
unsigned char di_size;
unsigned char do_size;
unsigned char di_path;
unsigned char do_path;
unsigned char di_kind;
unsigned char do_kind;
unsigned short di_top_address;
unsigned short do_top_address;
unsigned char sts_path;
unsigned char sts_kind;
unsigned short sts_top_address;
} OUT_PBSPRM2;
- slave_no
- Station number of slave
- range: from 0 to 125
- pad
- unused
- di_size
- size of DI data
- range: from 0 to 244
- unit: byte
- do_size
- size of DO data
- range: from 0 to 244
- unit: byte
- di_path
- PMC path number of DI data
- range: from 1 to 3
- do_path
- PMC path number of DO data
- range: from 1 to 3
- di_kind
- PMC address of DI data
- range: R or E
- do_kind
- PMC address of DO data
- range: R or E
- di_top_address
- top number of PMC address for DI data
- range: depends on the PMC address
- do_top_address
- top number of PMC address for DO data
- range: depends on the PMC address
- sts_path
- PMC path number of status data
- range: from 1 to 3
- sts_kind
- PMC address of status data
- range: R, E or Z
- sts_top_address
- top number of PMC address for status data
- range: depends on the PMC address
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
(-7) |
Version mismatch between the CNC/PMC and library Please use pbs_rd_param function. In this case, PMC address of status data is the followings. - sts_path = 1 - sts_kind ='R' - sts_address = 9094 |
|||||||||
(6) |
In order to get more information for this err_no return value, execute cnc_getdtailerr function. err_no of ODBERR structure.
|
|||||||||
(13) |
In order to get more information for this err_no return value, execute cnc_getdtailerr function. err_no of ODBERR structure.
|
As for the other return codes or the details, see "Return status of Data window function"
CNC option
This function need the following CNC option.
For HSSB connection,
CNC parameter
This function is not related to CNC parameter.
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | H |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.