Reads the various tool information of the specified tool group and tool use-order number. The following information are acquired.
- Tool length compensation number(always 0 in T series)
- Cutter radius compensation number(always 0 in T series)
- Tool information
0 | : | (refer to the following) |
1 | : | This tool is registered(available). |
2 | : | This tool has expired. |
3 | : | This tool was skipped. |
The currently used tool group and tool are referred by specifying 0 in "grp_no". However, in case that any tool group number has never be specified since power-on, 0 is stored.
In case of specifying 0 in "use_no", either the currently used tool for already used tool group or the first tool for not-used tool group is referred.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments
Specify the library handle. See "Library handle" for details.
Specify the tool group number.
Specify the tool use-order number.
Pointer to the IODBTD structure including the various tool information. The IODBTD structure is as follows.
typedef struct iodbtd {
short datano; /* Tool group number. */
short type; /* Tool use-order number. */
long tool_num; /* Tool number. */
long h_code; /* Tool length compensation number. */
long d_code; /* Cutter radius compensation number. */
long tool_inf; /* Tool information. */
} IODBTD ;
The following information are stored in "tld2" with binary format.
- tld2.datano
- Tool group number.
- tld2.type
- Tool use-order number.
- tld2.tool_num
- Tool number.
- tld2.h_code
- Tool length compensation number (always 0 in T series)
- tld2.d_code
- Cutter radius compensation number. (always 0 in T series)
- tld2.tool_inf
- Tool information.
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling |
---|---|
(3) |
The specification of tool group number(grp_no) is wrong. |
(4) |
The specification of tool use-order number(use_no) is wrong. |
(6) |
The tool life management function and the extended driver/library function are necessary. |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
This function need the following CNC option.
And this function is related to the following CNC option.
- Series 15/15i
This function is influenced by 1024/512 pairs of the tool life management.
- Series 16/18/21, 16i/18i/21i
This function is influenced by 512(M Series)/128(T Series) pairs of the tool life management.
- Series 0i-F, 30i
This function is influenced by additional pairs number of the tool life management.
the tool life management : 256 pairs of the tool life management on whole system, both of M and T Series additional pairs number of the tool life management : 1024 pairs of the tool life management on whole system, both of M and T Series
For HSSB connection,
The extended driver/library function are necessary.
For Ethernet connection,
The Ethernet function and the extended driver/library function are necessary. However, in case of Series 16i/18i/21i-B, 0i-B/C/D/F and 30i the required CNC option is as follows. When Embedded Ethernet is used,above two optional functions are not required.
When Ethernet board is used,
- only Ethernet function is required.
CNC parameter
This function is related to the following CNC parameter.
See the manual of CNC parameter for details.
6813
8132#0=1 (must be set)
6813
8132#0=1 (must be set)
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | X |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |