Description
- DATA SERVER The file in the current folder of the ATA card of DATA SERVER function delete.
- DATA SERVER Host The file in the current folder of the present connection host of DATA SERVER function delete.
- Embedded Ethernet The file in the current folder of the present connection host of an embedded Ethernet function delete.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
#include "fwlib32.h" or "fwlib64.h"FWLIBAPI short WINAPI cnc_dsremove(unsigned short FlibHndl, char *dev_name, char *file);
Arguments
Specify the library handle. See "Library handle" for details.
Specify the device name is as follows:
DATA SERVER | : | "DATA_SV" |
DATA SERVER Host | : | "DTSVR_HOST" |
Embedded Ethernet | : | "EMB_ETHER" |
- DATA SERVER The pointer of the variable area where the device name to specify is stored specify.
- DATA SERVER Host,embedded Ethernet The pointer to the delete file name is specified. Maximum of 128 characters of ASCII character string including NULL, and place the NULL at the end.
Maximum of 33 characters of ASCII character string including NULL,and place the NULL at the end.
The pointer of the variable area where the device name to specify is stored specify.
The specification which used the wild card('*','?')is also possible.
However, when '*' is used, the character after '*' cannot be specified.
(Example:The specification "12*4" cannot be performed.)
Only the folder name to delete is specified(path specification is not available).
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
(6) |
In order to get more information for this err_no return value, execute cnc_getdtailerr() function. The following details status will be set onto the member, err_no of ODBERR structure.
|
||||||||||||||||||||||||
(-1) |
DATA SERVER or embedded Ethernet is processing. |
||||||||||||||||||||||||
(5) |
The Specification of dev_name is wrong. |
||||||||||||||||||||||||
(14) |
In order to get more information for this err_no return value,In order to get more information for this err_no return value,cnc_getdtailerr() function. The following details status will be set onto the member, err_no of ODBERR structure.
|
As for the other return codes or the details, see "Return status of Data window function"
CNC option
For HSSB connection,
The DATA SERVER function and the extended driver/library function are necessary.
CNC parameter
This function is not related to CNC parameter.
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | X |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.
See Also