Description
- DATA SERVER Changing the file or folder name which exist in the current folder of the ATA card of DATA SERVER function.
- DATA SERVER Host Changing the file or folder name which exist in the current folder of the present connection host of DATA SERVER function.
- Embedded Ethernet Changing the file or folder name which exist in the current folder of the present connection host of an embedded Ethernet function.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
#include "fwlib32.h" or "fwlib64.h"FWLIBAPI short WINAPI cnc_dsrename(unsigned short FlibHndl, char *dev_name, char *src_name, char *dst_name);
Arguments
Specify the library handle. See "Library handle" for details.
Specify the device name is as follows:
DATA SERVER | : | "DATA_SV" |
DATA SERVER Host | : | "DTSVR_HOST" |
Embedded Ethernet | : | "EMB_ETHER" |
- DATA SERVER The folrder or filename before change specify.
- DATA SERVER Host, Embedded Ethernet Specify the only the folrder or filename before change.
Maximum of 33 characters of ASCII character string including NULL,the string must be NULL terminated.
Maximum of 128 characters of ASCII character string including NULL,the string must be NULL terminated.
- DATA SERVER Specify the only the folder or filename after change. Maximum of 33 characters of ASCII character string including NULL,the string must be NULL terminated.
- DATA SERVER Host, Embedded Ethernet Specify the only the folder or filename after change. Maximum of 128 characters of ASCII character string including NULL,the string must be NULL terminated.
It cannot change into the same name as the folder and and file which alreadty exist.
It cannot change into the same name as the folder and and file which alreadty exist.
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
(6) |
In order to get more information for this err_no return value, execute cnc_getdtailerr() function. The following details status will be set onto the member, err_no of ODBERR structure.
|
|||||||||||||||||||||||||||
(-1) |
DATA SERVER or embedded Ethernet is processing. |
|||||||||||||||||||||||||||
(5) |
Specification of dev_name is inaccuracy. |
|||||||||||||||||||||||||||
(14) |
In order to get more information for this err_no return value,In order to get more information for this err_no return value,cnc_getdtailerr() function. The following details status will be set onto the member, err_no of ODBERR structure.
|
As for the other return codes or the details, see "Return status of Data window function"
CNC option
For HSSB connection,
The DATA SERVER function and the extended driver/library function are necessary.
CNC parameter
This function is not related to CNC parameter.
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | X |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.