Description
Therefore, normal termination of this function shows that getting the file from the host computer has been started.
The result of getting file must be got by cnc_dtsvftpstat. Don't use the data sever function(except DNC operation) at the CNC side until either EW_OK or EW_DTSRVR as the completion status is got by cnc_dtsvftpstat after this function was finished.
* "Req." shows the start request for getting file by this function.
* "ret=" is the completion status when cnc_dtsvftpstat is done.
Throughout the prohibition term, the completion status of the following function is EW_BUSY.
-
cnc_dtsvftpget
cnc_dtsvftpput
cnc_dtsvdelete
cnc_dtsvrdpgdir
cnc_dtsvrdset
cnc_dtsvwrset
cnc_dtsvchkdsk
cnc_dtsvhdformat
Therefore, it is necessary to get either EW_OK or EW_DTSRVR as the completion status by cnc_dtsvftpstat when this function was executed successfully.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments : HSSB
Specify the library handle. See "Library handle" for details.
Specify the pointer to the file name in the host computer.
The specification of the file name of the host computer is as follows:
- Use ASCII code.
- The last character of the file name must be 'NULL'.
- The maximum length of the file name is 256 including 'NULL'.
- It is impossible to specify the path. (Specify the path by using cnc_dtsvwrset.)
- The lowercase can be used.
- The wild-card('*','?') cannot be used.
Specify the pointer to the file name in the DATA SERVER.
The specification of the file name of the DATA SERVER is as follows:
- Use ASCII code.
- The last character of the file name must be 'NULL'.
- It is impossible to specify the path. (The file is made in the directory "\PROG" of the DATA SERVER in case of the DATA SERVER board (10BASE-5), or in the directory "\NCDATA" of the DATA SERVER in case of the DATA SERVER board(10BASE-T).)
- The wild-card('*','?') cannot be used.
- Specify the MS-DOS form. (file name 8 char.+'.'+extension 3 char.+'NULL', total is within 13 char.)
<ex.> "XXXXXXXX.XXX" + NULL
However, the "O" number is managed as a file name now.<ex.> "O0001" + NULL
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling | ||||||
---|---|---|---|---|---|---|---|
(-1) |
Try again because DATA SERVER is processing. (There is a possibility of forgetting to call cnc_dtsvftpstat function.) |
||||||
(6) |
|
||||||
(14) |
In order to get more information for this err_no return value, execute cnc_getdtailerr function. The following details status will be set onto the member, err_no of ODBERR structure.
|
As for the other return codes or the details, see "Return status of Data window function"
CNC option
For HSSB connection,
CNC parameter
This function is not related to CNC parameter.
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | X |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.
See Also