Description
- DATA SERVER The file for DNC operation at the time of the storage mode of DATA SERVER function is set up.
- DATA SERVER Host The file for DNC operation at the time of the FTP mode or buffer mode of DATA SERVER function is set up.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
#include "fwlib32.h" or "fwlib64.h"FWLIBAPI short WINAPI cnc_wrdsdncfile(unsigned short FlibHndl, char *dev_name, char *dncfile);
Arguments
Specify the library handle. See "Library handle" for details.
Specify the device name is as follows:
DATA SERVER : "DATA_SV" DATA SERVER Host : "DTSVR_HOST"
- DATA SERVER The pointer to the variable area where the file name to set up is stored is specfied.
- DATA SERVER Host The pointer to the variable area where the file name to set up is stored is specfied.
The file name to receive 256 bytes or less of ASCII characters string including NULL.
The file name to receive 128 bytes or less of ASCII characters string including NULL.
It bocomes specfication of only a file name.
A connection host number and a folder turn into the host number and current folder which are connected now.
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
(6) |
In order to get more information for this err_no return value, execute cnc_getdtailerr() function. The following details status will be set onto the member, err_no of ODBERR structure.
|
|||||||||||||||||||||||||||
(-1) |
- Try again because DATA SERVER is processing. |
|||||||||||||||||||||||||||
(5) |
The Specification of dev_name is wrong. |
|||||||||||||||||||||||||||
(14) |
In order to get more information for this err_no return value,In order to get more information for this err_no return value,cnc_getdtailerr() function. The following details status will be set onto the member, err_no of ODBERR structure.
|
As for the other return codes or the details, see "Return status of Data window function"
CNC option
For HSSB connection,
The DATA SERVER function and the extended driver/library function are necessary.
CNC parameter
This function is not related to CNC parameter.
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | X |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.
See Also