Description
Set the connected host number and work folder for the M198 on DATA SERVER using FTP mode.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments
Specify the library handle. See "Library handle" for details.
It is able to set from 1 to 10.
It is able to set the number from 1 to 3.
The Ascii string less than 256 characters which included NULL.
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
(6) |
In order to get more information for this err_no return value, execute cnc_getdtailerr() function. The following details status will be set onto the member, err_no of ODBERR structure.
|
||||||||||||
(7) |
Writing to the parameter is failed. In order to get more information for this err_no return value, execute cnc_getdtailerr() function. The following details status will be set onto the member, err_no of ODBERR structure.
|
||||||||||||
(5) |
In order to get more information for this err_no return value, execute cnc_getdtailerr() function. The following details status will be set onto the member, err_no of ODBERR structure.
|
||||||||||||
(11) |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
For HSSB connection,
The DATA SERVER function and the extended driver/library function are necessary.
CNC parameter
This function is not related to CNC parameter.
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | X |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.