Description
Reads the target signal for the operation history.
Please use this function instead of cnc_rdhissgnl for Series 16i/18i/21i MODEL B with the extended operation history function.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments
Specify the library handle. See "Library handle" for details.
Pointer to the IODBSIG2 structure in which the operation history signal is stored. The IODBSIG2 structure is as follows.
typedef struct iodbsig2 {
short datano; /* Not used */
short type; /* Number of signals */
struct {
short ent_no; /* Registration sequence number */
short sig_no; /* Registered signal number */
char sig_name; /* Registered signal name */
char mask_pat; /* Signal mask pattern */
} data[45];
} IODBSIG2 ;
- type
- Number of signals can be registration
- Series 16i/18i/21i MODEL B, when the extended operation history function exists
- Other cases
45 is returned. Whole of data[0]~data[44] are effective. 20 is returned. Only data[0]~data[19] are effective. - ent_no
- Registration sequence number (from 1 to value of the type)
- sig_no
- Number of a registered signal
- Series 16i/18i/21i MODEL B, when the extended operation history function exists (the type equals to 45)
- Other cases (the type equals to 20)
X : 0~127 or 200~327 or 1000~1063 G : 0~511 or 1000~1511 or 2000~2511 Y : 0~127 or 200~327 or 1000~1063 F : 0~511 or 1000~1511 or 2000~2511 X : 0~127 or 1000~1063 G : 0~255 or 1000~1255 or 2000~2255 Y : 0~127 or 1000~1063 F : 0~255 or 1000~1255 or 2000~2255 - sig_name
- Name of a registered signal
0 : Not registered 1 : X 2 : G 3 : Y 4 : F - mask_pat
- Signal mask pattern
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling |
---|---|
(6) |
The extended driver/library function is necessary. |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
For HSSB connection,
For Ethernet connection,
The Ethernet function and the extended driver/library function are necessary. However, in case of Series 16i/18i/21i-B, 0i-B/C, the required CNC option is as follows. When Embedded Ethernet is used,above two optional functions are not required.
When Ethernet board is used,
- only Ethernet function is required.
In case of Series 16i/18i/21i MODEL B, this function is related to the extended operation history function.
CNC parameter
This function is related to the following CNC parameter.
See the manual of CNC parameter for details.
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | X |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.