Description
Writes the target signal for the operation history.
Please use this function instead of cnc_wrhissgnl for Series 30i, 0i-D/F and PMi-A.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments
Specify the library handle. See "Library handle" for details.
Pointer to the IODBSIG3 structure to set the various target signal information for the operation history. The IODBSIG3 structure is as follows.
typedef struct iodbsig3 {
short datano; /* Not used */
short type; /* Number of signals */
struct {
short ent_no; /* Registration sequence number */
short pmc_no; /* PMC number */
short sig_no; /* Registered signal number */
char sig_name; /* Registered signal name */
char mask_pat; /* Signal mask pattern */
} data[60];
} IODBSIG3 ;
- type
- Number of signals (from 1 to 60)
- pmc_no
- PMC number (1,2,3)
- ent_no
- Registration sequence number (from 1 to 60)
- sig_no
- Signal number to register
X : 0~127 G : 0~767 Y : 0~127 F : 0~767 - sig_name
- Signal address to register
0 : No registration 1 : X 2 : G 3 : Y 4 : F - mask_pat
- Signal mask pattern
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
(4) |
The specification of "Number of signals"(type) is wrong. |
|||||||||||||||
(5) |
In order to get more information for this err_no return value, execute cnc_getdtailerr function. The following detail status will be set onto the member, err_no of ODBERR structure.
|
|||||||||||||||
(6) |
The extended driver/library function is necessary. |
|||||||||||||||
(9) |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
For HSSB connection,
For Ethernet connection,
The Ethernet function and the extended driver/library function are necessary. However, in case of Series 0i-D/F, 30i and PMi-A, the required CNC option is as follows. When Embedded Ethernet is used,above two optional functions are not required.
When Ethernet board is used,
- only Ethernet function is required.
CNC parameter
This function is related to the following CNC parameter.
See the manual of CNC parameter for details.
3106#4=1,3195#6=0 (influenced by setting)
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | O |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.
See Also