Description
Reads data related to electrical discharge at power compensation ends.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments
Specify the library handle. See "Library handle" for details.
Specify the pointer to the array of ODBDISCHRG structure to store the data which related to electrical discharge at the end of power compensation.
The ODBDISCHRG structure is as follows.
typedef struct odbdischrg {
unsigned short aps; /* Power supply select flag */
unsigned short year; /* Year at power compensation ends */
unsigned short month; /* Month at power compensation ends */
unsigned short day; /* Day at power compensation ends */
unsigned short hour; /* Hour at power compensation ends */
unsigned short minute; /* Minute at power compensation ends */
unsigned short second; /* Second at power compensation ends */
short hpc; /* Peak power */
short hfq; /* Pulse frequency */
short hdt; /* Pulse duty */
short hpa; /* Actual power */
long hce; /* Power compensation coefficient */
long rfi[8]; /* RF current(RFI) */
long rfv[8]; /* RF voltage(RFV) */
long dci[8]; /* DC current(DCI) */
long dcv[8]; /* DC voltage(DCV) */
long dcw[8]; /* DC power(DCW) */
} ODBDISCHRG;
- aps
- Power supply select flag
#0 : PSU1 (Power supply 1) #1 : PSU2 (Power supply 2) : : #7 : PSU8 (Power supply 8) - year
- Year at power compensation ends(4 digits at Christian era)
- month
- Month at power compensation ends(1-12)
- day
- Day at power compensation ends(1-31)
- hour
- Hour at power compensation ends(0-23)
- minute
- Minute at power compensation ends(0-59)
- second
- Second at power compensation ends(0-59)
- hpc
- Peak power (0-7000)
- hfq
- Pulse frequency (0-2000)
- hdt
- Pulse duty (0-100)
- hpa
- Actual power (0-7000)
- hce
- Power compensation coefficient (0-65535)
- rfi[8]
- RF current(RFI) (0-65535) 8 data at each power supply.
- rfv[8]
- RF voltage(RFV) (0-65535) 8 data at each power supply.
- dci[8]
- DC current(DCI) (0-65535) 8 data at each power supply.
- dcv[8]
- DC voltage(DCV) (0-65535) 8 data at each power supply.
- dcw[8]
- DC power(DCW) (0-65535) 8 data at each power supply.
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling |
---|---|
(1) |
This function cannot be used except 16i/18i-L?30i/31i-LB. |
(6) |
The extended driver/library function are necessary. |
(9) |
Mistake of laser oscillator (parameter No.15030) |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
For HSSB connection,
For Ethernet connection,
The Ethernet function and the extended driver/library function are necessary. When Embedded Ethernet is used,above two optional functions are not required.
When Ethernet board is used,
- only Ethernet function is required.
CNC parameter
This function is related to the following CNC parameter.
See the manual of CNC parameter for details.
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | - |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.