Description
Reads the active cutting number, active piercing number and active slope number.
The data is stored in each member of the ODBLACTN structure.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments
Specify the library handle. See "Library handle" for details.
Pointer to the ODBLACTN structure including the active cutting number, active piercing number and active slope number. The ODBLACTN structure is as follows.
typedef struct odblactn {
short slct; /* Flag of valid data */
short act_proc; /* Active cutting number */
short act_pirce; /* Active piercing number */
short act_slop; /* Active slope number (Series 30i/31i-LB cannot be used.) */
short reserve[5]; /* (reserve) */
} ODBLACTN ;
- slct
- Flag of valid data is set.
bit 0 : Active cutting number bit 1 : Active piercing number bit 2 : Active slope number(Series 30i/31i-LB cannot be used.) bit 3,..,7 : (reserve) bit 8,..,15 : (not used) - * When a bit is 0, it means the corresponding data has no meaning.
- act_proc
- Active cutting number is set.
- ·Series 16i/18i-L
- (Output range: 1 to 10, Unit: none)
- ·Series 30i/31i-LB
- When addition of the cutting condition data option is not provided.
- (Output range: 1 to 10, Unit: none)
- When addition of the cutting condition data option is provided.
- (Output range: 1 to 30, Unit: none)
- act_price
- Active piercing number is set.
- ·Series 16i/18i-L
- (Output range: 101 to 103, Unit: none)
- ·Series 30i/31i-LB
- When addition of the cutting condition data option is not provided.
- (Setting range: 101 to 103)
- When addition of the cutting condition data option is provided.
- (Setting range: 101 to 110)
- act_slope
- Active slope number is set.
- ·Series 16i/18i-L
- (Output range: 301 to 305, Unit: none)
- ·Series 30i/31i-LB
- Series 30i/31i-LB cannot be used.
- reserve
- (reserve)
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling |
---|---|
(1) |
This function cannot be used except 16i/18i-L?30i/31i-LB. |
(6) |
The cutting condition setting function and the extended driver/library function are necessary. |
(9) |
Mistake of laser oscillator (parameter No.15030) |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
This function need the following CNC option.
For HSSB connection,
For Ethernet connection,
The Ethernet function and the extended driver/library function are necessary. When Embedded Ethernet is used,above two optional functions are not required.
When Ethernet board is used,
- only Ethernet function is required.
CNC parameter
This function is related to the following CNC parameter.
See the manual of CNC parameter for details.
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | - |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |