Description
Reads the assist gas selection of laser setting data.
The data is stored in each member of the IODBLAGSL structure.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments
Specify the library handle. See "Library handle" for details.
Pointer to the IODBLAGSL structure including the assist gas selection of laser setting data. The IODBLAGSL structure is as follows.
·Series 16i/18i-L
typedef struct iodblagsl {
short slct; /* Flag of valid data */
short ag_slt; /* Assist gas selection */
short agflow_slt; /* Assist gas flow selection */
short reserve[6]; /* (reserve) */
} IODBLAGSL ;
·Series 30i/31i-LB
typedef struct iodblagsl {
short slct; /* Flag of valid data */
short ag_slt; /* Assist gas selection */
short agflow_slt; /* Series 30i/31i-LB cannot be used. */
short ag_press; /* Assist gas pressure */
short ag_ready_t; /* Gas setting time */
short reserve[4]; /* (reserve) */
} IODBLAGSL ;
- slct
- Flag of valid data is set.
- ·Series 16i/18i-L
bit0 : Assist gas selection bit1 : Assist gas flow selection bit 2,..,7 : (reserve) bit 8,..,15 : (not used) - ·Series 30i/31i-LB
bit0 : Assist gas selection bit1 : Series 30i/31i-LB cannot be used. bit2 : Assist gas pressure bit3 : Gas setting time bit 4,..,15 : (not used) - * When a bit is 0, it means the corresponding data has no meaning.
- ag_slt
- Assist gas selection is set.
- agflow_slt
- Series 16i/18i-L
- Assist gas flow selection is set.
- Series 30i/31i-LB
- Series 30i/31i-LB cannot be used.
- ag_press
- ·Series 30i/31i-LB only
- Assist gas pressure is set.
- It corresponds to parameter No.15136.
- ag_ready_t
- ·Series 30i/31i-LB only
- Gas setting time is set.
- It corresponds to parameter No.15135.
- reserve
- (reserve)
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling |
---|---|
(1) |
This function cannot be used except 16i/18i-L, 30i/31i-LB. |
(6) |
The extended driver/library function is necessary. |
(9) |
Mistake of laser oscillator (parameter No.15030) |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
For HSSB connection,
For Ethernet connection,
The Ethernet function and the extended driver/library function are necessary. When Embedded Ethernet is used,above two optional functions are not required.
When Ethernet board is used,
- only Ethernet function is required.
CNC parameter
This function is related to the following CNC parameter.
See the manual of CNC parameter for details.
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | - |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.