Description
Reads the item of setting screen at power control. Each data is stored in the members within IODBPWRCTL.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments
Specify the library handle. See "Library handle" for details.
The data group number to read is set.
901 to 910 | power control data group number |
A pointer to the number of data items in power control is set. Specifies the number to read before calling the function. The number which actually read after calling the function is set.
A pointer to the IODBPWRCTL structure in which to return the data group of power control. The IODBPWRCTL structure is as follows.
typedef struct iodbpwrctl {
short slct; /* Flag of valid data */
short power_min; /* Minimum peak power */
short pwr_sp_zr; /* Peak power at feed rate = 0 */
short freq_min; /* Minimum pulse frequency */
short freq_sp_zr; /* Frequency at feed rate = 0 */
short duty_min; /* Minimum pulse duty */
short duty_sp_zr; /* Pulse duty at feed rate = 0 */
char feed_r_dec; /* Decimals places */
char reserve; /* (reserve) */
long feed_r; /* Allowable width of feed rate fluctuation */
short reserves[7]; /* (reserve) */
} IODBPWRCTL ;
- slct
- Flag of valid data is set.
bit 0 : Minimum peak power bit 1 : Peak power at feed rate = 0 bit 2 : Minimum pulse frequency bit 3 : Frequency at feed rate = 0 bit 4 : Minimum pulse duty bit 5 : Pulse duty at feed rate = 0 bit 6 : Allowable width of feed rate fluctuation bit 7,..,15 : (reserve) - * When a bit is 0, it means the corresponding data hasno meaning.
- power_min
- The minimum peak power (clamp value) is set.
- (Setting range:0 to 9999,Unit:W)
- pwr_sp_zr
- The peak power at feed rate = 0 is set.
- (Setting range:0 to 9999,Unit:W)
- freq_min
- The minimum pulse frequency is set.
- (Setting range:1 to 32767,Unit:Hz)
- freq_sp_zr
- The pulse frequency at feed rate = 0 is set.
- (Setting range:1 to 32767,Unit:Hz)
- duty_min
- The minimum pulse duty is set.
- (Setting range:0 to 100,Unit:%)
- duty_sp_zr
- The pulse duty at feed rate = 0 is set.
- (Setting range:0 to 100,Unit:%)
- feed_r_dec
- The number of decimals places at allowable width of feed rate fluctuation is set.
- (Setting range:0 to 9)
- The corresponding data is as follows.
- reserve
- (reserve)
- feed_r
- The allowable width of feed rate fluctuation is set.
- (Setting range:0 to 999999999,Unit:mm?inch(input unit))
- reserves
- (reserve)
decimals places | corresponding data |
---|---|
feed_r_dec | feed_r |
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling |
---|---|
(1) |
This function cannot be used except 30i/31i-LB. |
(2) |
Number of data(number) is wrong. |
(3) |
Start number(s_no) is wrong. |
(6) |
The cutting condition setting function and the extended driver/library function are necessary. |
(9) |
Mistake of laser oscillator (parameter No.15030) |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
This function need the following CNC option.
For HSSB connection,
For Ethernet connection,
The Ethernet function and the extended driver/library function are necessary. When Embedded Ethernet is used,above two optional functions are not required.
When Ethernet board is used,
- only Ethernet function is required.
CNC parameter
This function is related to the following CNC parameter.
See the manual of CNC parameter for details.
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | - |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.
See Also