Description
Reads the laser power data.
The data is stored in each member of the ODBLOPDT structure.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments
Specify the library handle. See "Library handle" for details.
Pointer to the ODBLOPDT structure including the laser power data. The ODBLOPDT structure is as follows.
·Series 16i/18i-L
typedef struct odblopdt {
short slct; /* Flag of valid data */
short pwr_mon; /* Power monitor value */
short pwr_ofs; /* Power offset */
short pwr_act; /* Actual laser power */
long feed_act; /* Actual feedrate */
short reserve[4]; /* (reserve) */
} ODBLOPDT ;
·Series 30i/31i-LB
typedef struct odblopdt {
short slct; /* Flag of valid data */
short pwr_mon; /* Power monitor value */
short pwr_ofs; /* Power offset */
short pwr_act; /* Actual laser power */
long feed_act; /* Actual feedrate */
char feed_dec; /* Decimals places */
char reserve; /* (reserve) */
short reserves[3];/* (reserve) */
} ODBLOPDT ;
- slct
- Flag of valid data is set.
bit 0 : Power monitor value bit 1 : Power offset bit 2 : Actual laser power bit 3 : Actual feedrate bit 4,..,7 : (reserve) bit 8,..,15 : (not used) - * When a bit is 0, it means the corresponding data has no meaning.
- pwr_mon
- Power monitor value is set.
- pwr_ofs
- Power offset is set.
- pwr_act
- Actual laser power is set.
- feed_act
- Actual feedrate is set.
- feed_dec
- ·Series 30i/31i-LB only
- decimals places in Actual feedrate is set.
- reserve
- (rerserve)
- reserves
- ·Series 30i/31i-LB only
- (rerserve)
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling |
---|---|
(1) |
This function cannot be used except 16i/18i-L, 30i/31i-LB. |
(6) |
The extended driver/library function is necessary. |
(9) |
Mistake of laser oscillator (parameter No.15030) |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
For HSSB connection,
For Ethernet connection,
The Ethernet function and the extended driver/library function are necessary. When Embedded Ethernet is used,above two optional functions are not required.
When Ethernet board is used,
- only Ethernet function is required.
CNC parameter
This function is related to the following CNC parameter.
See the manual of CNC parameter for details.
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | - |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.