Description
Notifies the end of verification of NC program to CNC.
(This function must be executed after cnc_verify4.)
There are cases where errors(EW_DATA, etc.) during execution of verifying NC program are returned by this function.
Further, this function does not return until the verification of the output data by cnc_verify4 is completed.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments
Specify the library handle. See "Library handle" for details.
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
(1) |
||||||||||
(5) |
In order to get more information for this err_no return value, execute cnc_getdtailerr function. The following detail status will be set onto the member, err_no of ODBERR structure.
|
|||||||||
(13) |
Downloading is disable in the current CNC status. (Machining, resetting, mode changing) See Description about the timing of error. |
|||||||||
(15) |
Alarm has occurred while downloading. See Description about the timing of error. |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
For HSSB connection,
CNC parameter
This function is related to the following CNC parameter.
See the manual of CNC parameter for details.
0000#0
3201#2,#5,#6
3202#0,#4
3204#3,#4
3210,3211
8900#0
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | O |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |
Note) 0i-C does not support the HSSB function.
See Also