Description
Reads the maximum number of tool group, the maximum number of tool within group and the maximum number of life count.
Universal Fanuc Driver
Fanuc Focas Library CD
Declaration
Arguments
Specify the library handle. See "Library handle" for details.
Pointer to the ODBTLINFO structure including the maximum number of tool group, the maximum number of tool within group and the maximum number of life count. The ODBTLINFO structure is as follows.
typedef struct odbtlinfo {
long max_group; /* maximum number of tool group */
long max_tool; /* maximum number of tool within group */
long max_minute; /* maximum number of life count (minutes) */
long max_cycle; /* maximum number of life count (cycles) */
} ODBTLINFO;
The following information are stored in "tlinfo" with binary format.
- max_group
- maximum number of tool group.
- max_tool
- maximum number of tool within group.
- max_minute
- maximum number of life count. (minutes)
- max_cycle
- maximum number of life count. (cycles)
Return
EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.
The major error codes are as follows.
Return code | Meaning/Error handling |
---|---|
(6) |
The tool life management function and the extended driver/library function are necessary. |
As for the other return codes or the details, see "Return status of Data window function"
CNC option
This function need the following CNC option.
And this function is related to the following CNC option.
- Series 15i
This function is influenced by 1024/512 pairs of the tool life management.
- Series 16i/18i/21i
This function is influenced by 512(M Series)/128(T Series) pairs of the tool life management.
- Series 0i-F, 30i
This function is influenced by additional pairs number of the tool life management.
the tool life management : 256 pairs of the tool life management on whole system, both of M and T Series additional pairs number of the tool life management : 1024 pairs of the tool life management on whole system, both of M and T Series
For HSSB connection,
The extended driver/library function are necessary.
For Ethernet connection,
The Ethernet function and the extended driver/library function are necessary. However, in case of Series 16i/18i/21i-B, 0i-B/C/D/F and 30i the required CNC option is as follows. When Embedded Ethernet is used,above two optional functions are not required.
When Ethernet board is used,
- only Ethernet function is required.
CNC parameter
This function is related to the following CNC parameter.
See the manual of CNC parameter for details.
6805#4 (Tool life management B)
6813
8132#0=1 (must be set)
6813
8132#0=1 (must be set)
CNC mode
This function can be used in any CNC mode.
Available CNC
0i-A | 0i-B/C(Note) | 0i-D | 0i-F | 15 | 15i | 16 | 18 | 21 | 16i-A | 18i-A | 21i-A | 16i-B | 18i-B | 21i-B | 30i-A | 30i-B | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M (Machining) | |||||||||||||||||
T (Turning) | - | ||||||||||||||||
LC (Loader) | - | - | - | - | - | - | - | - |
0i-D | 0i-F | 16i | 18i | 30i-A | 30i-B | |
---|---|---|---|---|---|---|
P (Punch press) | - | |||||
L (Laser) | - | - | - | - | ||
W (Wire) | - | - |
Power Mate i-D | |
Power Mate i-H | |
Power Motion i-A | X |
"O" | : | Both Ethernet and HSSB | |
"E" | : | Ethernet | |
"H" | : | HSSB | |
"X" | : | Cannot be used | |
"-" | : | None |