SECT_SP_SV_MON_AXIS_NOS
Number of axes
SECT_SP_SV_MON_AXIS_NAME
Axis name
SECT_SP_SV_MON_GAIN
gain
SECT_SP_SV_MON_DRP
Droop
SECT_SP_SV_MON_REV_SPEED
Rotational speed
SECT_SP_SV_MON_SEND_SPD
Feed speed
SECT_SP_SV_MON_LOAD_CURRENT
Load current
SECT_SP_SV_MON_MAX_CURRENT1
MAX current 1
SECT_SP_SV_MON_MAX_CURRENT2
MAX current 2
SECT_SP_SV_MON_MAX_CUR3
MAX current 3
SECT_SP_SV_MON_OVER_LOAD
Overload
SECT_SP_SV_MON_C_LOAD
Regenerative load
SECT_SP_SV_MON_RUL_TRQ
Estimated disturbance torque
SECT_SP_SV_MON_MAX_TRQ
MAX disturbance torque
SECT_SP_SV_MON_INARTIA
Load inertia ratio
SECT_SP_SV_MON_AFLT_FX
AFLT frequency
SECT_SP_SV_MON_AFLT_GAIN
AFLT gain
SECT_SP_SV_MON_DISP_AMP
Amplifier display
SECT_SP_SV_MON_ALARM
Alarm 1
SECT_SP_SV_MON_ALARM2
Alarm 2
SECT_SP_SV_MON_ALARM3
Alarm 3
SECT_SP_SV_MON_CYCLE_COUNTER
Cycle counter
SECT_SP_SV_MON_GRID_SPC
Grid spacing
SECT_SP_SV_MON_GRID_VOL
Grid amount
SECT_SP_SV_MON_MCHN_POS
Machine value
SECT_SP_SV_MON_MOTOR_EDGE_FB
Motor end FB
SECT_SP_SV_MON_MCHN_EDGE_FB
Machine end FB
SECT_SP_SV_MON_FB_ERROR
FB error
SECT_SP_SV_MON_DFB_CORRECT_DATA
DFB correction amount
SECT_SP_SV_MON_MON_LPOINT
Remaining command
SECT_SP_SV_MON_MANUAL_INT
Manual interrupt amount
SECT_SP_SV_MON_ABS_POS
Absolute position command
SECT_SP_SV_MON_CMP_ERR
Machine error correction amount
SECT_SP_SV_MON_SYNC_ERR
Overlapping synchronization error
SECT_SP_SV_MON_SYNC_ERR_P
Superposition synchronization error 0 + p
SECT_SP_SV_MON_SYNC_ERR_M
Superimposition synchronization error 0 - p
SECT_SP_SV_MON_SYNC_ERR_MAX
Superimposition synchronization error p - p
SECT_SP_SV_MON_CONTROL_IN_1L
Control input 1 L
SECT_SP_SV_MON_CONTROL_IN_1H
Control input 1 H
SECT_SP_SV_MON_CONTROL_IN_2L
Control input 2L
SECT_SP_SV_MON_CONTROL_IN_2H
Control input 2H
SECT_SP_SV_MON_CONTROL_IN_3L
Control input 3L
SECT_SP_SV_MON_CONTROL_IN_3H
Control input 3H
SECT_SP_SV_MON_CONTROL_IN_4L
Control input 4L
SECT_SP_SV_MON_CONTROL_IN_4H
Control input 4H
SECT_SP_SV_MON_CONTROL_IN_5L
Control input 5L
SECT_SP_SV_MON_CONTROL_IN_5H
Control input 5H
SECT_SP_SV_MON_CONTROL_IN_6L
Control input 6L
SECT_SP_SV_MON_CONTROL_IN_6H
Control input 6H
SECT_SP_SV_MON_CONTROL_OUT_1L
Control output 1 L
SECT_SP_SV_MON_CONTROL_OUT_1H
Control output 1 H
SECT_SP_SV_MON_CONTROL_OUT_2L
Control output 2 L
SECT_SP_SV_MON_CONTROL_OUT_2H
Control output 2H
SECT_SP_SV_MON_CONTROL_OUT_3L
Control output 3 L
SECT_SP_SV_MON_CONTROL_OUT_3H
Control output 3H
SECT_SP_SV_MON_CONTROL_OUT_4L
Control output 4 L
SECT_SP_SV_MON_CONTROL_OUT_4H
Control output 4H
SECT_SP_SV_MON_CONTROL_OUT_5L
Control output 5 L
SECT_SP_SV_MON_CONTROL_OUT_5H
Control output 5H
SECT_SP_SV_MON_CONTROL_OUT_6L
Control output 6L
SECT_SP_SV_MON_CONTROL_OUT_6H
Control output 6H
SECT_SP_SV_MON_ABS0
ABS0
SECT_SP_SV_MON_AMP_TYPE_NAME
Amplifier type name
SECT_SP_SV_MON_AMP_MANUFACTURED_NUM
Amp model number
SECT_SP_SV_MON_SW_VERSION
S / W version
SECT_SP_SV_MON_CONTROL_FORMULA
control method
SECT_SP_SV_MON_MOTOR_EDGE_DETECTOR
Motor end detector
SECT_SP_SV_MON_DGN_MOT_SNO
Model number of motor end detector
SECT_SP_SV_MON_MCHN_EDGE_DETECTOR
Machine end detector
SECT_SP_SV_MON_DGN_MAC_DT
Machine end detector number
SECT_SP_SV_MON_MOTOR
motor
SECT_SP_SV_MON_WORKING_TIME
Operating time
SECT_SP_SV_MON_ALARM_HISTORY1_TIME
Alarm history (hour) 1
SECT_SP_SV_MON_ALARM_HISTORY2_TIME
Alarm history (hour) 2
SECT_SP_SV_MON_ALARM_HISTORY3_TIME
Alarm history (hour) 3
SECT_SP_SV_MON_ALARM_HISTORY4_TIME
Alarm history (time) 4
SECT_SP_SV_MON_ALARM_HISTORY5_TIME
Alarm history (time) 5
SECT_SP_SV_MON_ALARM_HISTORY6_TIME
Alarm history (hour) 6
SECT_SP_SV_MON_ALARM_HISTORY7_TIME
Alarm history (hour) 7
SECT_SP_SV_MON_ALARM_HISTORY8_TIME
Alarm history (time) 8
SECT_SP_SV_MON_ALARM_HISTORY1_NUM
Alarm history (number) 1
SECT_SP_SV_MON_ALARM_HISTORY2_NUM
Alarm history (number) 2
SECT_SP_SV_MON_ALARM_HISTORY3_NUM
Alarm history (number) 3
SECT_SP_SV_MON_ALARM_HISTORY4_NUM
Alarm history (number) 4
SECT_SP_SV_MON_ALARM_HISTORY5_NUM
Alarm history (number) 5
SECT_SP_SV_MON_ALARM_HISTORY6_NUM
Alarm history (number) 6
SECT_SP_SV_MON_ALARM_HISTORY7_NUM
Alarm history (number) 7
SECT_SP_SV_MON_ALARM_HISTORY8_NUM
Alarm history (number) 8
SECT_SP_SV_MON_MNT1
MNT 1
SECT_SP_SV_MON_MNT2
MNT 2
SECT_SP_SV_MON_MNT3
MNT 3
SECT_SP_SV_MON_MNT4
MNT 4
SECT_SP_SV_MON_SYS
SYS

 

Privacy notice

This website uses cookies. By continuing to use it you agree to our privacy policy. 

https://www.inventcom.net/support/citizen-mitsubishi-commands/data-on-servo-monitor-spindle-type-servo

Support | Citizen Mitsubishi Commands | Overview

Here yo can find a list of command sections for Mitsubishi CNC controllers on Citizen and... [read more]
Support | Citizen Mitsubishi Commands | Overview

Support | Citizen Mitsubishi Commands | Axis independent parameter

Axis name Basic Specification Para # 11 abson Absolute position set # 1 SET Absolute position set # 2 base Absolute position set SET_FIN Machine end E - G Axis specification para... [read more]
Support | Citizen Mitsubishi Commands | Axis independent parameter

Support | Citizen Mitsubishi Commands | Buffer correction

Start buffer correction Buffer correction end Acquire buffer correction status Buffer correction point acquisition (O number) Acquire buffer correction point (block) Buffer... [read more]
Support | Citizen Mitsubishi Commands | Buffer correction

Support | Citizen Mitsubishi Commands | Data on alarm

Absolute value alarm: attribute              : Sub 1              : Sub 2              :number Servo alarm: attribute              : Sub 1              : Sub 2... [read more]
Support | Citizen Mitsubishi Commands | Data on alarm

Support | Citizen Mitsubishi Commands | Data on arbitrary axis superposition

Arbitrary superimposition control data 1 Arbitrary superimposition control data 2 Arbitrary superimposition control data 3 Arbitrary superimposition control data 4 Arbitrary... [read more]
Support | Citizen Mitsubishi Commands | Data on arbitrary axis superposition

Support | Citizen Mitsubishi Commands | Data on current NC program and running status

O: Program number (main program) N: Sequence number (main program) B: Block number (main program) O: Program number (subprogram) N: Sequence number (subprogram) B: Block number... [read more]
Support | Citizen Mitsubishi Commands | Data on current NC program and running status

Support | Citizen Mitsubishi Commands | Data on date time etc

Power on time Automatic operation time Auto start time External integration 1 hour External integration 2 hours date Times of Day Power-on time (unit: motion cycle) Automatic... [read more]
Support | Citizen Mitsubishi Commands | Data on date  time etc

Support | Citizen Mitsubishi Commands | Data on forced output of device

Modal output device 1 Modal output number 1 Modal output data 1 Modal output device 2 Modal output number 2 Modal output data 2 Modal output device 3 Modal output number 3 Modal... [read more]
Support | Citizen Mitsubishi Commands | Data on forced output of device

Support | Citizen Mitsubishi Commands | Data on I F of super option

Data setting completion flag PC command NC status Point balance Used points Purchase point Subtraction point 1 Subtraction point 2 Warning point 1 Warning point 2 See:... [read more]
Support | Citizen Mitsubishi Commands | Data on I  F of super option

Support | Citizen Mitsubishi Commands | Data on M S T B function

M directive S command (1st spindle) S command (second main spindle) S directive (third spindle) S command (fourth main spindle) S command (fifth spindle) S directive (sixth... [read more]
Support | Citizen Mitsubishi Commands | Data on M  S  T  B function

Support | Citizen Mitsubishi Commands | Data on Machine Para Open I F

Machine para opening I / F 1 Machine para opening I / F 2 Machine para opening I / F 3 Machine para opening I / F 4 Machine para opening I / F 5 Machine para opening I / F 6... [read more]
Support | Citizen Mitsubishi Commands | Data on Machine Para Open I  F

Support | Citizen Mitsubishi Commands | Data on machine specification

Stored stroke limit (+) # 2014 OT + Stored stroke limit (-) # 2015 OT- Axis parameter # 8208 Soft limit + Axis parameter # 8204 Soft limit - Rotational axis # 1017 rot Diameter... [read more]
Support | Citizen Mitsubishi Commands | Data on machine specification

Support | Citizen Mitsubishi Commands | Data on memory read write

Memory read / write 1 byte data Memory read / write 2 byte data Memory read / write 4 byte data See: IIoT... [read more]
Support | Citizen Mitsubishi Commands | Data on memory read  write

Support | Citizen Mitsubishi Commands | Data on message notification

Message notification information Message notification busy flag Message notification status Driver processing time Message reception function processing time See:... [read more]
Support | Citizen Mitsubishi Commands | Data on message notification

Support | Citizen Mitsubishi Commands | Data on PLC switch load meter display

PLC switch name PLC switch input signal PLC switch input signal (collective) PLC switch output signal PLC switch output signal (collective) Road meter comment See:... [read more]
Support | Citizen Mitsubishi Commands | Data on PLC switch load meter display

Support | Citizen Mitsubishi Commands | Data on position switch

Axis name 1 Dog position 1-1 Dog position 2-1 Axis name 2 Dog position 1-2 Dog position 2-2 Axis name 3 Dog position 1-3 Dog position 2-3 Axis name 4 Dog position 1-4 Dog... [read more]
Support | Citizen Mitsubishi Commands | Data on position switch

Support | Citizen Mitsubishi Commands | Data on power supply monitor servo axis main axis

Power Supply Quantity Power supply name Unit type name Unit serial number S / W version Connected drive Recovered energy Power-supply voltage PN bus voltage MINPN bus voltage Bus... [read more]
Support | Citizen Mitsubishi Commands | Data on power supply monitor servo axis main axis

Support | Citizen Mitsubishi Commands | Data on program correction I F in program check

Reverse Block Stop Request Buffer correctability information See: IIoT Device Driver for Citizen Mitsubishi... [read more]
Support | Citizen Mitsubishi Commands | Data on program correction I  F in program check

Support | Citizen Mitsubishi Commands | Data on servo axis name position state etc

Number of axes (reset state) Axis state Machine position (double type) Current position (double type) Work coordinate position (double type) Remaining command Origin · Zero... [read more]
Support | Citizen Mitsubishi Commands | Data on servo axis name position state etc

Support | Citizen Mitsubishi Commands | Data on servo monitor servo axis

Number of axes Axis name gain Droop Rotational speed Feed speed Load current MAX current 1 MAX current 2 MAX current 3 Overload Regenerative load Estimated disturbance torque MAX... [read more]
Support | Citizen Mitsubishi Commands | Data on servo monitor servo axis

Support | Citizen Mitsubishi Commands | Data on super option

Option bit 1 Option bit 2 Option bit 3 Option bit 4 Option bit 5 Option bit 6 Option bit 7 Option bit 8 Option bit 9 Option bit 10 Option bit 11 Option bit 12 Option bit 13... [read more]
Support | Citizen Mitsubishi Commands | Data on super option

Support | Citizen Mitsubishi Commands | Data on tool life management Lifetime management method I II

Tool life management ?: Time Tool life management ?: Number of times Tool life management ?: Status Tool life management ?: Tool No. Tool life management ?: Status Tool life... [read more]
Support | Citizen Mitsubishi Commands | Data on tool life management Lifetime management method I II

Support | Citizen Mitsubishi Commands | Data on tool offset

Tool correction group number Tool correction amount: Edge wear amount: X Tool correction amount: cutting edge wear amount: Z Tool correction amount: Edge wear amount: Y Tool... [read more]
Support | Citizen Mitsubishi Commands | Data on tool offset

Support | Citizen Mitsubishi Commands | Data on tuning of NC specification

Effective line Inch unit # 1041 I_inch Input unit # 1003 Edit lock B During automatic operation Automatic operation active Machining program tape storage length MACHINE Maker... [read more]
Support | Citizen Mitsubishi Commands | Data on tuning of NC specification

Support | Citizen Mitsubishi Commands | Data on variable

Local Variable Macro Subpro Number of sets of common variable (# 100 ~) Common variable (# 100 ~) Number of sets of common variable (# 500 ~) Common variable (# 500 ~) Custom... [read more]
Support | Citizen Mitsubishi Commands | Data on variable

Support | Citizen Mitsubishi Commands | Data on waveform display screen

Sampling period Sampling type Sampling start trigger signal Sampling start trigger level Sampling data size Waveform display Horizontal scale Sampling data code Sampling data... [read more]
Support | Citizen Mitsubishi Commands | Data on waveform display screen

Support | Citizen Mitsubishi Commands | Data on work offset

G 58 Work coordinate system offset G59 Work coordinate system offset G54 Work coordinate system offset (extension I / F) G55 Work coordinate system offset (extended I / F) G56... [read more]
Support | Citizen Mitsubishi Commands | Data on work offset

Support | Citizen Mitsubishi Commands | Data related to auxiliary axis J2CT control

Number of auxiliary axes Axis valid / invalid information driving Operation adjustment mode Absolute position set Position set state Operation mode Operating parameters... [read more]
Support | Citizen Mitsubishi Commands | Data related to auxiliary axis J2CT control

Support | Citizen Mitsubishi Commands | Data relating to auxiliary axis J2CT monitor

Droop Rotational speed Load current MAX current 1 MAX current 2 Load factor Regenerative load Current station number present location Target station number Command position... [read more]
Support | Citizen Mitsubishi Commands | Data relating to auxiliary axis J2CT monitor

Support | Citizen Mitsubishi Commands | Data relating to spindle monitor including spindle type servo

Number of axes Axis name gain Droop Rotational speed Load MAX current 1 MAX current 2 MAX current 3 Overload Regenerative load Estimated disturbance torque MAX disturbance torque... [read more]
Support | Citizen Mitsubishi Commands | Data relating to spindle monitor including spindle type servo

Support | Citizen Mitsubishi Commands | Data relating to the operating state etc of the spindle

First spindle rotation speed Second spindle rotation speed Third spindle rotation speed Fourth spindle rotation speed Fifth spindle rotation speed Sixth spindle rotation speed... [read more]
Support | Citizen Mitsubishi Commands | Data relating to the operating state etc of the spindle

Support | Citizen Mitsubishi Commands | Event I F

DPRNT function start / end notice DPRNT execution state MelPostMessageEx start notification MelPostMessageEx start end notice MelPostMsgBufferEx start notification... [read more]
Support | Citizen Mitsubishi Commands | Event I  F

Support | Citizen Mitsubishi Commands | Key history data

History function control History data update check Read history data See: IIoT Device Driver for Citizen... [read more]
Support | Citizen Mitsubishi Commands | Key history data

Support | Citizen Mitsubishi Commands | M600L compatible I F for Citizens group

Network option 06 Network option 07 Network option 08 Network option 09 Network option 11 Network option 11 Network option 12 Network option 13 Network options 14 Network option... [read more]
Support | Citizen Mitsubishi Commands | M600L compatible I  F for Citizens group

Support | Citizen Mitsubishi Commands | MELDAS NET failure diagnosis information

Presence / absence of fault diagnosis information See: IIoT Device Driver for Citizen Mitsubishi... [read more]
Support | Citizen Mitsubishi Commands | MELDAS NET failure diagnosis information

Support | Citizen Mitsubishi Commands | MELDAS diagnostic data

Initialization of diagnostic information Check for existence of diagnostic information SRAM maximum size of diagnostic information DRAM maximum size of diagnostic information NC... [read more]
Support | Citizen Mitsubishi Commands | MELDAS diagnostic data

Support | Citizen Mitsubishi Commands | Memory Read Write

See: IIoT Device Driver for Citizen Mitsubishi controllers... [read more]
Support | Citizen Mitsubishi Commands | Memory Read Write

Support | Citizen Mitsubishi Commands | Parameter

G00 dry run Macro single Ignore middle point Machine lock high speed ABS / INC address G04 Time fixed Interference avoidance Command unit 10 times Decimal type 2 G00... [read more]
Support | Citizen Mitsubishi Commands | Parameter

Support | Citizen Mitsubishi Commands | PLC device

Device B (one shot) link relay Device C (one shot) counter input Device C (one shot) counter output Device E (one shot) special relay Device SM (one shot) special relay Device F... [read more]
Support | Citizen Mitsubishi Commands | PLC device

Support | Citizen Mitsubishi Commands | Simulation I F

Mode set Mode reset Forwarding information Interpolation type Coordinate system type Data precision type Data transfer request See:... [read more]
Support | Citizen Mitsubishi Commands | Simulation I  F
Modified: 2024-03-26