Command | Default Data Type | Description | Part | Axis | R/W | Data Range |
---|
M_SSEC_UPOPE_COUNT_KIND(x)
| T_UCHAR | Counter type 1 to 6 (x=1 to 6) | -- | -- | RW | 0 to 255 |
M_SSEC_UPOPE_AUT_MANU_SW
| T_CHAR | Display switch between automatic/manual | -- | -- | RW | 0 to 2 |
M_SSEC_UPOPE_EDIT_UNDO
| T_CHAR | Edit undo enabled | -- | -- | RW | 0,1 |
M_SSEC_UPOPE_TOPSEARCH_AUTO
| T_CHAR | Auto top search | -- | -- | RW | 0,1 |
M_SSEC_UPOPE_AUTO_BACKUP_DAY1
| T_CHAR | Auto backup day 1 | -- | -- | RW | -1 to 31 |
M_SSEC_UPOPE_AUTO_BACKUP_DAY2
| T_CHAR | Auto backup day 2 | -- | -- | RW | 0 to 31 |
M_SSEC_UPOPE_AUTO_BACKUP_DAY3
| T_CHAR | Auto backup day 3 | -- | -- | RW | 0 to 31 |
M_SSEC_UPOPE_AUTO_BACKUP_DAY4
| T_CHAR | Auto backup day 4 | -- | -- | RW | 0 to 31 |
M_SSEC_UPOPE_AUTO_BACKUP_DEV
| T_CHAR | Auto backup device | -- | -- | RW | 0 to 2 |
M_SSEC_UPOPE_3D_TOFS_SELECT
| T_CHAR | 3D tool ofs select | -- | -- | RW | 0,1 |
M_SSEC_UPOPE_MASS_EDIT_SELECT
| T_CHAR | Mass edit select | -- | -- | RW | 0,1 |
M_SSEC_UPOPE_TREG_REPEAT_INVALID
| T_CHAR | T-register duplication check disabled | -- | -- | RW | 0,1 |
M_SSEC_UPOPE_HIDE_EDIT_IO_MENU
| T_CHAR | Hide Edit-IO menu | -- | -- | RW | 0,1 |
M_SSEC_UPOPE_MEAS_CONFIRM_MSG
| T_CHAR | Measure-Confirmation message exists | -- | -- | RW | 0,1 |
M_SSEC_UPOPE_SYS1_SPNO
| T_CHAR | Spindle No. on part sys 1 display | -- | -- | RW | 0x00 to 0x66 |
M_SSEC_UPOPE_SYS2_SPNO
| T_CHAR | Spindle No. on part sys 2 display | -- | -- | RW | 0x00 to 0x66 |
M_SSEC_UPOPE_SYS3_SPNO
| T_CHAR | Spindle No. on part sys 3 display | -- | -- | RW | 0x00 to 0x66 |
M_SSEC_UPOPE_SYS4_SPNO
| T_CHAR | Spindle No. on part sys 4 display | -- | -- | RW | 0x00 to 0x66 |
M_SSEC_UPOPE_OFS_ABSINPUT
| T_CHAR | ï¼Input menu disabled: Compensation | -- | -- | RW | 0,1 |
M_SSEC_UPOPE_VAR_ABSINPUT
| T_CHAR | ï¼Input menu disabled: Variable | -- | -- | RW | 0,1 |
M_SSEC_UPOPE_DIS_SET_LIMIT
| T_CHAR | Remote display/setting operation limit | -- | -- | RW | 0 to 2 |
M_SSEC_UPOPE_HIDE_MEAS_SCRN
| T_CHAR | Hide measure screen | -- | -- | RW | 0,1 |
M_SSEC_UPOPE_TOOLOFS_INPUT
| T_CHAR | Prohibit shape compensation amount setting | -- | -- | RW | 0,1 |
M_SSEC_UPOPE_WEAROFS_INPUT
| T_CHAR | Prohibit wear compensation amount setting | -- | -- | RW | 0,1 |